Franklin Electric's Cerus® X-Drive Low Harmonic Pump Panels are engineered to optimize demanding water systems by delivering reliable power while mitigating input distortion. Designed and thoroughly tested to meet IEEE-519 standards, these panels integrate the intuitive installation of Cerus X-Drive's variable frequency drives with intelligent harmonic mitigation. The application-specific firmware and compatibility with the FE Connect® mobile app ensure smooth startup, efficient operation, and long-term system health.

Overview


Features & Benefits

Full-Featured VFD Solution for Your Application

  • Available as NEMA 3R-rated pump panels, ideal for submersible and centrifugal applications.
  • Powered by Franklin Electric’s Cerus X-Drive, featuring application-specific firmware for streamlined setup, quick startups, and reliable protection.
  • Advanced features include multi-VFD control for up to 8 VFDs, pre-PID control (pipe fill), 2nd PID control, dual demand, and pipe leak protection.
  • *Models are available for up to 600 hp for centrifugal applications and 500 hp for submersible applications 

Protect Pumping Systems & Support Grid Compliance

  • Mitigate the impact of harmonic distortion and prevent premature equipment failure, leading to unplanned downtime.
  • Cerus X-Drive Low Harmonic Pump Panels come with a built-in intelligent passive harmonic filter that minimizes total harmonic distortion (THD), extending the life of your motors, drives, and infrastructure.
  • Engineered and tested to support regulatory compliance, minimize the risk of utility-imposed penalties, and enhance the overall stability and efficiency of the power grid.
  • Ensure consistent performance and lower operating costs — even in the most demanding environments.

Integrated Connectivity & Automation-Ready Features

  • Bluetooth-enabled for onsite connectivity and collaboration, powered by the FE Connect mobile app
  • Integrated Programmable Logic Controller (PLC) helps address automation tasks in advanced industrial applications and beyond
  • Compatible with SCADA and automation systems using Modbus RTU/ASCII and BACnet MS/TP communication protocols
  • Expandable with optional cards, including Modbus TCP/IP and digital input/output modules

From Selection to Service — Support You Can Rely On

  • Our most-requested panel solutions are engineered and application-ready, pre-configured by expert teams to help you confidently tackle field jobs.
  • With FE Select, you can size, configure, and quote the right product using your performance specs in minutes.
  • Every unit is assembled and shipped from our UL 508A-certified Oregon facility, ensuring top-tier quality and fast fulfillment.
  • Backed by our industry-leading technical support and field service engineers, ensuring you’re supported every step.
  • From start-up to service, unlock real-time remote access to Franklin’s support team or your internal experts for live collaboration via FE Connect’s One-to-One™ feature 

Order Information


Standard Pump Panel UL Type 3R 460V Centrifugal Pumping Systems

Item Output Horsepower Input Phase Maximum Output Current Branch Protection Included
XCLH4BH010-3A 10 HP Three-Phase 14 A YES
XCLH4BH015-3A 15 HP Three-Phase 21 A YES
XCLH4BH020-3A 20 HP Three-Phase 27 A YES
XCLH4BH025-3A 25 HP Three-Phase 34 A YES
XCLH4BH030-3A 30 HP Three-Phase 40 A YES
XCLH4BH040-3A 40 HP Three-Phase 52 A YES
XCLH4BH050-3A 50 HP Three-Phase 65 A YES
XCLH4BH060-3A 60 HP Three-Phase 77 A YES
XCLH4BH075-3A 75 HP Three-Phase 96 A YES
XCLH4BH100-3A 100 HP Three-Phase 124 A YES
XCLH4BH125-3A 125 HP Three-Phase 156 A YES
XCLH4BH150-3A 150 HP Three-Phase 180 A YES
XCLH4BH200-3A 200 HP Three-Phase 240 A YES
XCLH4BH250-3A 250 HP Three-Phase 302 A YES
XCLH4BH300-3A 300 HP Three-Phase 361 A YES
XCLH4BH350-3A 350 HP Three-Phase 414 A YES
XCLH4BH400-3A 400 HP Three-Phase 477 A YES
XCLH4BH500-3A 500 HP Three-Phase 515 A YES
XCLH4BH600-3A 600 HP Three-Phase 590 A YES

Standard Pump Panel UL Type 3R 460V Submersible Pumping Systems

Item Output Horsepower Input Phase Maximum Output Current Branch Protection Included
XSLH4BH010-3A 10 HP Three-Phase 17.3 A YES
XSLH4BH015-3A 15 HP Three-Phase 25.8 A YES
XSLH4BH020-3A 20 HP Three-Phase 30.3 A YES
XSLH4BH025-3A 25 HP Three-Phase 38.2 A YES
XSLH4BH030-3A 30 HP Three-Phase 45.2 A YES
XSLH4BH040-3A 40 HP Three-Phase 61.6 A YES
XSLH4BH050-3A 50 HP Three-Phase 78.1 A YES
XSLH4BH060-3A 60 HP Three-Phase 92.3 A YES
XSLH4BH075-3A 75 HP Three-Phase 107 A YES
XSLH4BH100-3A 100 HP Three-Phase 142 A YES
XSLH4BH125-3A 125 HP Three-Phase 188 A YES
XSLH4BH150-3A 150 HP Three-Phase 219 A YES
XSLH4BH200-3A 200 HP Three-Phase 249 A YES
XSLH4BH250-3A 250 HP Three-Phase 282 A YES
XSLH4BH300-3A 300 HP Three-Phase 425 A YES
XSLH4BH350-3A 350 HP Three-Phase 462 A YES
XSLH4BH400-3A 400 HP Three-Phase 533 A YES
XSLH4BH500-3A 500 HP Three-Phase 647 A YES