    • Constant water pressure with a wide range of settings (25 to 80 psi)
    • Single-phase input power
    • FE Connect Smartphone app for advanced settings and monitoring (NEMA 3R only excluding SD2W)
    • User-configurable motor frequency range (NEMA 3R only excluding SD2W)
    • Easy installation
    • Soft-start feature prevents water hammer and increases motor life
    • Works with small pressure tanks or existing larger tanks
    • Advanced filtering to remove radio frequency interference
    • UL and cUL listed
    • Built-in diagnostics and protection
    • Surge Protection
    • Short circuit
    • Underload
    • Overheated controller
    • Undervoltage
    • Broken pipe detection (NEMA 3R only excluding SD2W)
    • Locked pump
    • User-configurable underload off time (NEMA 3R only excluding SD2W)
    • Open circuit

    MonoDrive Models

    MonoDrive and MonoDriveXT are designed to convert a conventional ½ hp to 2 hp pump system to a variable speed constant pressure system by simply replacing the 3-wire control box and pressure switch.

    • Single-phase input, 3-wire motor control
    • Plug & play
    • ½ hp to 2 hp performance
    • Easily replaceable fan kit
    • Easy to install
    • UL and cUL listed
    • NEMA 3R and NEMA 4 enclosure options (indoor/outdoor)

    SubDrive 3-Phase Models

    SubDrive15, SubDrive20, SubDrive30, SubDrive75, SubDrive100, SubDrive150, and SubDrive300 are designed for three-phase motors to provide constant pressure with three-phase performance using single-phase input power.

    • Single-phase input, three-phase motor control
    • Plug & play
    • ¾ hp to 5 hp performance
    • Smooth running
    • Easy to install
    • Easily replaceable fan kit
    • High starting torque
    • UL and cUL listed
    • NEMA 3R and NEMA 4 enclosure options (indoor/outdoor)

    SubDrive2W

    SubDrive2W is designed to convert a conventional ½ hp, ¾ hp, and 1 hp pump system to a variable speed constant pressure system by simply replacing the pressure switch. Maximum pump output using the SD2W is similar to the performance achieved using a conventional pressure switch. Therefore, the pump selection criteria are the same as if a pressure switch were used. (Refer to the pump manufacturer’s literature for details of the pump selection procedure.)

    • Single-phase input, 2-wire motor control
    • Plug & play
    • ½ hp, ¾ hp, or 1 hp performance
    • Easily replaceable air filter kit
    • Easy retrofit installation
    • Easily replaceable fan kit
    • NEMA 3R rated enclosure
    • UL and cUL listed

    Related

  • NEMA 3R Constant Pressure Controllers

    VFDEnclosure TypeModel No.
    MonoDrive NEMA 3R, VARIABLE FREQUENCY5870205003C
    MonoDriveXT NEMA 3R, VARIABLE FREQUENCY5870205203C
    SubDrive15 NEMA 3R, VARIABLE FREQUENCY5870205103C
    SubDrive20 NEMA 3R, VARIABLE FREQUENCY5870205303C
    SubDrive30 NEMA 3R, VARIABLE FREQUENCY5870205403C
    SubDrive50 NEMA 3R, VARIABLE FREQUENCY5870205503C
    SubDrive2WNEMA 3R, VARIABLE FREQUENCY5870203223

    NEMA 4 Constant Pressure Controllers

    VFDEnclosure TypeModel No.
    MonoDrive NEMA 4 VARIABLE FREQUENCY5870203114
    MonoDriveXT NEMA 4 VARIABLE FREQUENCY5870204114
    SubDrive 100 NEMA 4, VARIABLE FREQUENCY5870204104
    SubDrive 150 NEMA 4, VARIABLE FREQUENCY5870204154
    SubDrive 300 NEMA 4, VARIABLE FREQUENCY5870206300
    SubDrive 75 NEMA 4, VARIABLE FREQUENCY5870203384

    Accessories

    AccessoriesDetailUsed WithPart No.
    Air Screen Kit Helps prevent insects from
    entering and damaging the
    internal components of the drive
    SD2W 225835901
    Air Screen Kit Helps prevent insects from
    entering and damaging the
    internal components of the drive
    SD15, SD20, SD30, MD,
    MDXT non-”C” models
    226550901
    Analog Pressure Transducer 4-20mA analog pressure
    transducer used with “C” models
    (includes 10 ft cable)
    All “C” models - 100 PSI226905902
    226905903
    226905904
    Analog Pressure
    Transducer Cable Kit
    Outdoor rated cable to
    connect analog pressure
    transducer to "C" drive models
    All "C" models - 10 ft 226910901
    All "C" models - 25 ft 226910902
    All "C" models - 50 ft 226910903
    All "C" models - 100 ft 226910904
    All "C" models - 150 ft 226910905
    All "C" models - 200 ft 226910906
    Duplex Alternator Allows a water system
    to alternate between
    two parallel pumps
    controlled by separate SubDrives
    All Models 5850012000
    Duplex Alternator Cable Kit Communication cable kit
    required to use the built-in
    Duplex Alternator function
    in "C" drive models
    All "C" models - 10 ft 226895901
    All "C" models - 50 ft 226895902
    All "C" models - 100 ft 226895903
    Enhanced Display
    Board Replacement Kit
    Replacement board for drives
    that have a damaged display
    All "C" models 226540912
    Enhanced Pressure
    Input Board Replacement Kit
    Replacement board for "C"
    drives that have experienced
    a surge on the Enhanced
    Pressure Input Board.
    All "C" models 226540902
    Filter (Input) Filter used on the input side of
    drive to help eliminate interference
    All Models 225198901
    Filter (Output) Filter used on the output
    side of the drive to help
    eliminate interference
    All Models (excluding SD300) 225300901
    Filter (System) Filter used as a system filter
    on input/output of the drive to
    help eliminate interference
    SD300 225650901
    Filter (Surge Capacitors) Capacitor used on the service panel
    to help eliminate power interference
    All SubDrives/MonoDrives
    (excl. SD2W and SD300)
    225199901
    Heatsink Cover Kit Assists in preventing critters from
    entering and blocking fan area
    All NEMA 4 models
    (excluding SD300)
    225805901
    Lightning Arrestor Single-phase (Input Power) Single-phase (Input Power) 150814902
    Low Voltage Kit Used to make adjustments to
    the voltage of the SubDrive
    SubDrive SD300 225950901
    Moisture Sensor Kit External sensor device that
    shuts down the drive when
    water is detected.
    All "C" models226770901
    NEMA 1 Fan Replacement KitReplacement fan
    (Date code prior to 08L)
    SD75 and MD 225635905
    NEMA 1 Fan Replacement KitReplacement fan
    (Date code 08L and after)
    SD75 and MD 225635908
    NEMA 1 Fan Replacement KitReplacement fan
    (with Date Code prior to 08K)
    SD100, SD150, and MDXT 225635907
    NEMA 1 Fan Replacement KitReplacement fan
    (with Date Code 08K and after)
    SD100, SD150, and MDXT225635909
    NEMA 3R Fan Replacement KitReplacement fan
    (with Date Code prior to 08K)
    SD75 and MD 225635907
    NEMA 3R Fan Replacement KitReplacement fan SD2W 225635910
    NEMA 3R Fan Replacement KitReplacement fan SD50 226545903
    NEMA 3R Fan Replacement KitReplacement fan
    (with Date Code 14L and after)
    SD15 and MD 226545901
    NEMA 3R Fan Replacement KitReplacement fan
    (with Date Code 14L and after)
    SD20, SD30, and MDXT 226545902
    NEMA 4 External
    Cooling Fan Replacement Kit
    Replacement External fan
    (with Date Code prior to 14L)
    SD75 and MD 225635901
    NEMA 4 External
    Cooling Fan Replacement Kit
    Replacement External fan
    (with Date Code prior to 14L)
    SD100, SD150, and MDXT225635902
    NEMA 4 External
    Cooling Fan Replacement Kit
    Replacement External fan
    (include 2 fans)
    SD300 225635903
    NEMA 4 Internal
    Stirring Fan Replacement Kit
    Replacement Internal Stirring fan
    (with Date Code prior to 14L)
    SD75, SD100, SD150,
    SD300, MD, MDXT
    225635904
    NEMA 4 Auxiliary Relay Board Offers Run-Indication Relay
    (for Date Codes 09J through 14K)
    All NEMA 4 models
    (excluding SD300)
    225755901
    NEMA 4 Option Card Offers Run-Indication Relay &
    Underload Extended Off-Time
    (Date Codes 09J–14K)
    All NEMA 4 models
    (excluding SD300)
    225880901
    Pressure Sensor
    (High: 75-150 psi, NSF 61 rated)
    Adjusts pressure in the water
    system from 75-150 psi
    (2-leaded cable)
    All Models 225970901
    Pressure Sensor
    (Std.: 25-80 psi, NSF 61 rated)
    Adjusts pressure in the water
    system from 25-80 psi
    (2-leaded cable)
    All Models 223995901
    Pressure Sensor/Pressure
    Shut-Off Switch Kit
    Kit includes pressure sensor
    (25-80 psi, NSF 61 rated),
    pressure shut-off switch
    (100 psi) and 10 foot cable
    (4-leaded cable)
    SD300 225495901
    Pressure Sensor Input
    Board Replacement
    Replacement board for drives
    that have experienced a
    surge on the pressure sensor input
    (with Date codes 14L and after)
    All Models 226540901
    Sensor Cable Kit (Indoor)100 feet of 22 AWG cable
    (2-leaded cable)
    All models excluding
    SD2W and SD300
    223995902
    Sensor Cable Kit (Indoor)100 feet of 22 AWG cable
    (4-leaded cable)
    SD300 225495902
    Sensor Cable Kit (outdoor)100 feet of 22 AWG cable
    (2-leaded cable)
    All Models 226941901
    Sensor Direct Burial Cable Designed to run in an underground
    trench without conduit to surround it
    (4-leaded cable)
    All Models - 10 ft (3 m) 225800901
    All Models - 30 ft (9 m)225800902
    All Models - 100 ft (30.5 m) 225800903
    Tank Drawdown Kit Allows the use of water stored
    in the tank during low flow demands
    MDN3R, MDXTN3R, SD15,
    SD20, SD30, SD2W, & SD300
    225770901
    Tank Drawdown Kit Allows use of tank-stored water
    during low-flow demands
    (Date codes prior to 14L)
    SD75N4, SD100N4, SD150N4,
    MDN4, and MDXTN4
    (requires Auxiliary Relay
    Board or NEMA 4 Option Card)
    225770901
    • *N1 = NEMA 1 (Indoors), N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)
  • SubDrive Accessories

    AccessoriesDetailUsed withPart Number
    Air Screen KitAssists in preventing insects from entering and
    damaging the internal components of the drive
    SD2W225 835 901
    Air Screen KitAssists in preventing insects from entering and
    damaging the internal components of the drive
    All SubDrives and MonoDrives
    (excluding SD2W and SD300)
    226 550 901
    Duplex AlternatorAllows a water system to alternate between two
    parallel pumps controlled by separate SubDrives
    All Models585 001 2000
    Filter (Input)Filter used on the input side of drive to help
    eliminate interference
    All Models225 198 901
    Filter (Output)Filter used on the output side of the drive to help
    eliminate interference
    All Models (excluding SD300)225 300 901
    Filter (System)Filter used as a system filter on input and output
    of the drive to help eliminate interference
    SD300225 650 901
    Filter (Surge Capacitors)Capacitor used on the service panel to help
    eliminate power interference
    All SubDrives and MonoDrives
    (excluding SD2W and SD300)
    225 199 901
    Heatsink Cover KitAssists in preventing critters from entering
    and blocking fan area
    All NEMA 4 models
    (excluding SD300)
    225 805 901
    Lightning ArrestorSingle-phase (Input Power)Single-phase (Input Power)150 814 902
    Low Voltage KitUsed to make adjustments to the voltage
    of the SubDrive
    SD300225 950 901
    NEMA 1 Fan
    Replacement Kit
    Replacement fan (with Date Code prior to 08L)SD75 and MD225 635 905
    NEMA 1 Fan
    Replacement Kit
    Replacement fan (with Date Code 08L and after)SD75 and MD225 635 908
    NEMA 1 Fan
    Replacement Kit
    Replacement fan (with Date Code prior to 08K)SD100, SD150, and MDXT225 635 907
    NEMA 1 Fan
    Replacement Kit
    Replacement fan (with Date Code 08K and after)SD100, SD150, and MDXT225 635 909
    NEMA 3R Fan
    Replacement Kit
    Replacement fan (with Date Code prior to 08K)SD75 and MD225 635 907
    NEMA 3R Fan
    Replacement Kit
    Replacement fanSD2W225 635 910
    NEMA 3R Fan
    Replacement Kit
    Replacement fan (with Date Code 14L and after)SD15 and MD226 545 901
    NEMA 3R Fan
    Replacement Kit
    Replacement fan (with Date Code 14L and after)SD20, SD30, and MDXT226 545 902
    NEMA 4 External Cooling
    Fan Replacement Kit
    Replacement External fan (with Date
    Code prior to 14L)
    SD75 and MD225 635 901
    NEMA 4 External Cooling
    Fan Replacement Kit
    Replacement External fan (with Date
    Code prior to 14L)
    SD100, SD150, and MDXT225 635 902
    NEMA 4 External Cooling
    Fan Replacement Kit
    Replacement External fan (include 2 fans)SD300225 635 903
    NEMA 4 Internal Stirring
    Fan Replacement Kit
    Replacement Internal Stirring fan (with
    Date Code prior to 14L)
    SD75, SD100, SD150,
    SD300, MD, MDXT
    225 635 904
    NEMA 4 Auxiliary
    Relay Board
    Offers Run-Indication Relay (for Date
    Codes 09J through 14K)
    All NEMA 4 models
    (excluding SD300)
    225 755 901
    NEMA 4 Option CardOffers Run-Indication Relay and Underload Extended
    Off-Time (for Date Codes 09J through 14K)
    All NEMA 4 models
    (excluding SD300)
    225 880 901
    Pressure Sensor
    (High: 75-150 psi,
    NSF 61 rated)
    Adjusts pressure in the water system from
    75-150 psi (2-leaded cable)
    All Models225 970 901
    Pressure Sensor
    (Standard Replacement:
    25-80 psi, NSF 61 rated)
    Adjusts pressure in the water system from
    25-80 psi (2-leaded cable)
    All Models223 995 901
    Pressure Sensor /
    Pressure Shut-Off
    Switch Kit
    Kit includes pressure sensor (25-80 psi, NSF 61 rated),
    pressure shut-off switch (100 psi) and 10 foot cable
    (4-leaded cable)
    SD300225 495 901
    Pressure Sensor Input
    Board Replacement
    Replacement board for drives that have experienced
    a surge on the pressure sensor input (with Date
    Codes 14L and after)
    All Models226 540 901
    Sensor Cable Kit (indoor)100 feet of 22 AWG cable (2-leaded cable)All models excluding
    SD2W and SD300
    223 995 902
    Sensor Cable Kit (indoor)100 feet of 22 AWG cable (4-leaded cable)SD300225 495 902
    Sensor Direct Burial CableDesigned to be run in a trench underground
    without the use of conduit to surround it
    (4-leaded cable)
    All Models - 10 ft (3 m)
    All Models - 30 ft (9 m)
    All Models - 100 ft (30.5 m)
    225 800 901
    225 800 902
    225 800 903
    Tank Drawdown KitAllows the use of water stored in the tank
    during low flow demands
    MDN3R, MDXTN3R, SD15,
    SD20, SD30, SD2W, and SD300
    225 770 901
    Tank Drawdown KitAllows the use of water stored in the tank during
    low flow demands (with Date Codes prior to 14L)
    SD75N4, SD100N4, SD150N4,
    MDN4, and MDXTN4 (requires
    Auxiliary Relay Board or
    NEMA 4 Option Card)
    225 770 901
    • *N1 = NEMA 1 (Indoors), N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)

    MonoDrive

    MonoDrive (NEMA 3R)
    Model 5870205003C
    MonoDrive (NEMA 4)
    Model 5870203114
    Input from
    Power Source
    Voltage208/230 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)5.7 Amps (RMS) 1/2 hp, 0.37 kW system
    8.7 Amps (RMS) 3/4 hp, 0.55 kW system
    11 Amps (RMS) 1 hp, 0.75 kW system
    5.7 Amps (RMS) 1/2 hp, 0.37 kW system
    8.7 Amps (RMS) 3/4 hp, 0.55 kW system
    11 Amps (RMS) 1 hp, 0.75 kW system
    Power Factor~ 0.951.0 (constant)
    Power (idle)4 Watts35 Watts
    Power (max)2500 Watts1150 Watts (1/2 hp, 0.37 kW) system
    1750 Watts (3/4 hp, 0.55 kW) system
    2150 Watts (1 hp, 0.75 kW) system
    Wire Gauge Size(s)Consult Federal, State, and Local codes
    for branch circuit installations
    Consult Federal, State, and Local codes
    for branch circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire)Single-phase (3-wire)
    Frequency Range30-63 Hz30-60 Hz
    Current (max)Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
    Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
    Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
    Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
    Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
    Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity20-95%, non-condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 16-3/4” x 5-1/4”
    (25 x 42.5 x 13 cm)
    17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    Controller Size(B)
    (approximate)
    Weight20 lbs (9 kg)24.14 lbs (10.95 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    FE Motor214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
    214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire
    214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire (default)
    214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    MonoDriveXT

    MonoDriveXT (NEMA 3R)
    Model 5870205203C
    MonoDriveXT (NEMA 4)
    Model 5870204114
    Input from
    Power Source
    Voltage208/230 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)13 Amps (RMS) 1.5 hp, 1.1 kW system13 Amps (RMS) 1.5 hp, 1.1 kW system
    16 Amps (RMS) 2 hp, 1.5 kW system16 Amps (RMS) 2 hp, 1.5 kW system
    Power Factor~ 0.951.0 (constant)
    Power (idle)5 Watts65 Watts
    Power (max)4200 Watts2500 Watts (1.5 hp, 1.1 kW) system
    3100 Watts (2 hp, 1.5 kW) system
    Wire Gauge Size(s)Consult Federal, State, and
    Local codes for branch
    circuit installations
    Consult Federal, State, and
    Local codes for branch
    circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire)Single-phase (3-wire)
    Frequency Range30-63 Hz30-60 Hz
    Current (max)Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
    Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
    Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
    Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 and 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity20-95%, non-condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    Weight26 lbs (11.8 kg)28.32 lbs (12.84 kg)
    For Use With(C)Pump (60 Hz)1.0 hp (0.75 kW) pump with 214508-series motor
    1.5 hp (1.1 kW) pump with 224300-series motor
    2.0 hp (1.5 kW) pump with 224301-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.5 hp (1.1 kW) pump with 224300-series motor
    2.0 hp (1.5 kW) pump with 224301-series motor
    FE Motor214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
    214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire (default)
    224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive15 and SubDrive20

    SubDrive15 (NEMA 3R) (D)SubDrive20 (NEMA 3R) (D)
    Model No.Indoor/OutdoorModel 5870205103CModel 5870205303C
    Input from
    Power Source
    Voltage208/230 VAC208/230 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)12 Amps19 Amps
    Power Factor~ 0.95~ 0.95
    Power (idle)4 Watts5 Watts
    Power (max)2500 Watts4200 Watts
    Wire Gauge Size(s)Consult Federal, State,
    and Local codes for branch
    circuit installations
    Consult Federal, State,
    and Local codes for branch
    circuit installations
    Output to
    Motor
    VoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire) OR Three-phaseSingle-phase (3-wire) OR Three-phase
    Frequency Range30-77 Hz (3/4 hp, 0.55 kW) pump
    30-72 Hz (1 hp, 0.75 kW) pump
    30-60 Hz (1.5 hp, 1.1 kW) pump
    30-63 Hz (Single-phase Motors)
    30-78 Hz (1hp, 0.75 kW) pump
    30-72 Hz (1.5 hp, 1.1 kW) pump
    30-60 Hz (2 hp, 1.5 kW) pump
    30-63 Hz (Single-phase Motors)
    Current (max)5.9 A / phase8.1 A / phase
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #14 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 122 °F (-25 °C to 50 °C)
    Relative Humidity
    (NEMA 3R)
    20-95%, non-condensing20-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions
    Weight
    9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    26 lbs (11.8 kg)
    9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    26 lbs (11.8 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with
    214505-series motor
    0.75 hp (0.55 kW) pump with
    214507-series motor
    1.0 hp (0.75 kW) pump with
    214508-series motor
    0.75 hp (0.55 kW), 1.0 hp
    (0.75 kW) 1.5 hp (1.1 kW) pump
    with 234514-series motor
    1.0 hp (0.75 kW) pump
    with 214508-series motor
    1.5 hp (1.1 kW) pump
    with 224300-series motor
    2.0 hp (1.5 kW) pump
    with 224301-series motor
    0.75 hp (0.55 kW), 1.0 hp
    (0.75 kW), 1.5 hp (1.1 kW) pump
    with 234514-series motor
    1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
    2.0 hp (1.5 kW) pump
    with 234315-series motor
    FE Motor214505-series
    (0.5 hp, 0.37 kW) single-phase,
    3-wire 214507-series
    (0.75 hp, 0.55 kW)
    single-phase, 3-wire 214508-series
    (1.0 hp, 0.75 kW)
    single-phase, 3-wire 234514-series
    (1.5 hp, 1.1 kW) three-phase
    214508-series (1.0 hp, 0.75 kW)
    single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW)
    single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW)
    single-phase, 3-wire
    234514-series (1.5 hp, 1.1 kW)
    three-phase
    234315-series (2.0 hp, 1.5 kW)
    three-phase
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • (D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications in the manual apply.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive30 and SubDrive75

    SubDrive30 (NEMA 3R) (D)
    Model 5870205403C
    SubDrive75 (NEMA 4)
    Model 5870203384
    Input from
    Power Source
    Voltage208/230 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)23 Amps11 Amps (RMS)
    Power Factor~ 0.951.0 (constant)
    Power (idle)5 Watts35 Watts
    Power (max)4.2 kW2400 Watts
    Wire Gauge Size(s)Consult Federal, State,
    and Local codes for branch
    circuit installations
    Consult Federal, State,
    and Local codes for branch
    circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire) OR Three-phaseThree-Phase (3-wire)
    Frequency Range30-78 Hz (1.5 hp, 1.1 kW) pump30-80 Hz (3/4 hp, 0.55 kW) pump
    30-70 Hz (2 hp, 1.5 kW) pump30-70 Hz (1 hp, 0.75 kW) pump
    30-60 Hz (3 hp, 2.2 kW) pump30-60 Hz (1.5 hp, 1.1 kW) pump
    30-63 Hz (Single-Phase Motors)
    Current (max)10.9 A / phase5.9 Amps (RMS, each phase)
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 and 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity20-95%, non-condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 19-3/4” x 5-1/4”17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    Weight(25 x 50 x 13 cm)
    24.14 lbs (10.95 kg)
    26 lbs (11.8 kg)
    For Use With(C)Pump (60 Hz)1.0 hp (0.75 kW) pump
    with 214508-series motor
    1.5 hp (1.1 kW) pump
    with 224300-series motor
    2.0 hp (1.5 kW) pump
    with 224301-series motor
    0.75 hp (0.55 kW), 1.0 hp
    (0.75 kW), or 1.5 hp (1.1 kW)
    pump with 234514-series motor
    1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
    or 2.0 hp (1.5 kW) pump
    with 234315-series motor
    1.5 hp (1.1 kW), 2.0 hp (1.5 kW),
    or 3.0 hp (2.2 kW) pump with
    234316-series motor
    3/4 hp (0.55 kW) [default]
    1 hp (0.75 kW)
    1.5 hp (1.1 kW)
    FE Motor214508-series (1.0 hp, 0.75 kW)
    single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW)
    single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW)
    single-phase, 3-wire
    234514-series (1.5 hp, 1.1 kW) three-phase
    234315-series (2.0 hp, 1.5 kW) three-phase
    234316-series (3.0 hp, 2.2 kW) three-phase
    234514 - series (1.5 hp, 1.1 kW)
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • (D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications in the manual apply.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive100 and SubDrive150

    SubDrive100 (NEMA 4)SubDrive150 (NEMA 4)
    Model No.Indoor/OutdoorModel 5870204104Model 5870204154
    Input from
    Power Source
    Voltage190-260 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)19 Amps (RMS)23 Amps (RMS)
    Power Factor1.0 (constant)1.0 (constant)
    Power (idle)65 Watts65 Watts
    Power (max)3800 Watts4600 Watts
    Wire Gauge Size(s)Consult Federal, State, and Local
    codes for branch circuit installations
    Consult Federal, State, and Local
    codes for branch circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutThree-phase (3-wire)Three-phase (3-wire)
    Frequency Range30-80 Hz (1 hp, 0.75 kW) pump30-80 Hz (1.5 hp, 1.1 kW) pump
    30-70 Hz (1.5 hp, 1.1 kW) pump30-70 Hz (2 hp, 1.5 kW) pump
    30-60 Hz (2 hp, 1.5 kW) pump30-60 Hz (3 hp, 2.2 kW) pump
    Current (max)8.1 Amps (RMS, each phase)10.9 Amps (RMS, each phase)
    Wire Gauge Size(s)#6 - #18 * ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity0-100%, condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions
    Weight
    17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    28.32 lbs (12.84 kg)
    17-1/2" x 16-3/8" x 11-3/8"
    (44.45 x 41.59 x 28.89 cm)
    28.32 lbs (12.84 kg)
    For Use With(C)Pump (60 Hz)1 hp (0.75 kW) [default]
    1.5 hp (1.1 kW)
    2 hp (1.5 kW)
    1.5 hp (1.1 kW) [default]
    2 hp (1.5 kW)
    3 hp (2.2 kW)
    FE Motor234315 - series (2 hp, 1.5 kW)234316 - series (3 hp, 2.2 kW)
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive300 and SubDrive50

    SubDrive300 (NEMA 4)SubDrive50 (NEMA 3R)
    Model No.Indoor/OutdoorModel 58702063005870205503C
    Input from
    Power
    Source
    Voltage220-260 VAC208/230 /- 10% VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)36 Amps (RMS)36 Amps (RMS)
    Power Factor1.0 (constant)0.95
    Power (idle)65 Watts7 Watts
    Power (max)7200 Watts7200 Watts
    Wire Gauge
    Size(s)
    Consult Federal, State,
    and Localcodes for
    branch circuit installations
    Consult Federal, State, and Local
    codes for branch circuit installations
    Output
    to Motor
    VoltageAdjusts with FrequencyVariable based on frequency
    Phase OutThree-phase (3-wire)Single-phase (3-wire) OR three-phase
    Frequency
    Range
    30-80 Hz
    (3 hp, 2.2 kW) pump


    30-70 Hz
    (5 hp, 3.7 kW) pump
    30-78 Hz: 1/2-rated mismatched pump with three-phase motor
    30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-phase motor
    30-60 Hz: Matched pump with three-phase motor
    30-63 Hz: Matched pump with single-phase motor
    Current (max)17.8 Amps (RMS, each phase)17.8 A (three-phase), 17.0 A (single-phase)
    Wire Gauge
    Size(s)
    #2 - #18 * ga.#6 - #12 * ga.
    Pressure
    Setting
    Factory preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment
    Range
    25-80 psi (1.7 - 5.5 bar)Analog Transducer: 5-95 psi (0.3 - 6.6 bar)
    Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (@ 230 VAC input)
    -13 °F to 125 °F
    (-25 °C to 50 °C)
    -13 °F to 122 °F
    (-25 °C to 50 °C)
    Relative
    Humidity
    0-100%, condensing20-95%, non-condensing
    Controller
    Size(B)
    (approximate)
    Outer
    Dimensions
    Weight
    19-7/8” x 17-1/2” x 14-1/4”
    (50.48 x 44.45 x 36.20 cm)
    35.15 lbs (15.94 kg)
    26 1/8" x 15 3/8" x 11 1/2"
    (66 x 39 x 29 cm)
    31 lbs (14.1 kg)
    For Use
    With(C)
    Pump (60 Hz)3 hp (2.2 kW) [default]
    5 hp (3.7 kW)
    0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.5 hp (1.1 kW) pump with 224300-series motor
    2.0 hp (1.5 kW) pump with 224301-series motor
    3.0 hp (2.2 kW) pump with 224302-series motor
    0.5hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp (0.75 kW) pump w/ 234513-series motor
    0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump w/ 234514-series motor
    1.0 hp (0.75 kW), 2.0 hp (1.5 kW), or 2.0 hp (1.5 kW) pump w/ 234315-series motor
    1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump w/ 234316-series motor
    3.0 hp (2.2 kW) or 5.0 hp (3.7 kW) pump w/ 234317-series motor
    FE Motor234317-series
    (5 hp, 3.7 kW)
    214505-series (0.5hp, 0.37 kW) single-phase, 3-wire
    214507-series (0.75hp, 0.55 kW) single-phase, 3-wire
    214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
    224302-series (3.0 hp, 2.2 kW) single-phase, 3-wire
    234513-series (1.0 hp, 0.75 kW) three-phase
    234514-series (1.5 hp, 1.1 kW) three-phase
    234315-series (2.0 hp, 1.5 kW) three-phase
    234316-series (3.0 hp, 2.2 kW) three-phase
    234317-series (5.0 hp, 3.7 kW) three-phase
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive2W

    SubDrive2W (NEMA 3R)
    Model No.Indoor/OutdoorModel 5870203223
    Input from
    Power Source
    Voltage207-260 VAC
    Phase InSingle-phase
    Frequency60/50 Hz
    Current (max)14 Amps (RMS)
    (For circuit breaker sizing)
    Power Factor0.7 (approximate)
    Power (idle)20 Watts
    Power (max)1900 Watts
    Wire Gauge Size(s)Consult Federal, State, and Local
    codes for branch circuit installations
    Output to MotorVoltageAdjusts with Frequency
    Phase OutSingle-phase (2-wire)
    Frequency Range30-60 Hz
    Current (max)6 Amps (RMS) 1/2 hp, 0.37 kW system
    8 Amps (RMS) 3/4 hp, 0.55 kW system
    10.4 Amps (RMS) 1 hp, 0.75 kW system
    Wire Gauge Size(s)#6 - #18 * ga.
    Pressure SettingFactory preset50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity10-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions
    Weight
    12-1/4” x 16-1/2” x 9”
    (31.1 x 41.9 x 22.9 cm)
    15.0 lbs (6.80 kg)
    For Use With(C)Pump (60 Hz)1/2 hp pump/motor with 244505-series
    3/4 hp pump/motor with 244507-series [default]
    1 hp pump/motor with 244508-series
    FE MotorNot Available
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.