3Ø, 50/60 Hz, 200~600 VAC, 1-130 FLA (Differs per model)

IQ Logo

FE Select - Configure & Quote

U.S.A. Canada
Features
Order Info
Specs & Accessories
Downloads
  • Integrated electronic motor and pump protection

    • Class S electronic overload
    • Specifically designed protection for submersible motors
    • Built-in 1.15 service factor compensation
    • Underload (dry-run protection)
    • Current phase unbalance protection
    • Cycle fault protection
    • Locked rotor and stall protection
    • Out of calibration
    • Detects if overload FLA dial is improperly set

    Multi-voltage operating range with automation I/O

    • Accepts 200-600 VAC directly, true plug and play
    • Includes a dry contact auto-run input and fault relay output
    • Optional run timer - adjustable up to 12 hours
    • Starter will run for selected time then return to OFF until another run command is given

    Industrial grade construction

    • Door mounted heavy-duty HOA switch
    • Housed in an outdoor rated, gasketed, NEMA 3R enclosure
    • NEMA/IEC rated magnetic contactors feature 2.5 million electrical cycles at full rated current

    Optional circuit breaker disconnect (Service Entrance rated)

    • UL 489 circuit breaker provides branch and short circuit protection
    • No fuses required – saves time and money
    • Lockable handle for safety
  • 200~600 V Including Service Entrance Breaker Disconnect NEMA Type 3R Enclosed

    Part Number200 V - 460 V
    SFA Range** (A)
    600 V
    SFA Range** (A)
    3-PHASE HP (UL) / Max. SFA**Contactor
    NEMA Size
    200 V230 V460 V600 V
    HPSFAHPSFAHPSFAHPSFA
    SSP3R-S0-J-G156~86~8282858580
    SSP3R-S0-J-G208~118~113113117.5111011
    SSP3R-S0P-J-G3011~1711~17317517101715170+
    SSP3R-S1-J-G4016~2216~225227.522152220221
    SSP3R-S1P-J-G5020~2820~287.5281028202825281+
    SSP3R-S1P-J-G6024~3224~327.532103220323032
    SSP3R-S2-J-G8032~4532~4510451545304540452
    SSP3R-S2-J-G10040~5240~521552155240525052
    SSP3R-S3-J-G12550~7150~7120712571507160713
    SSP3R-S3P-J-G15060~8060~7725803080608075773+
    SSP3R-S3P-J-G20080~DPV*NA3092401047596--
    SSP3R-S4-J-G20080~114NA301144011475114--4
    SSP3R-S4-J-G250100~DPV*NA4012050130100124--
    • Smartstart Pump Starter - 3-Phase, 50/60 Hz, 200~600 VAC
    • NEMA Type 3R Enclosed - Combination Starter
    • Includes Service Entrance Circuit Breaker Disconnect

    200~600 V Disconnect not Included NEMA Type 3R Enclosed

    Part Number200 V - 460 V
    SFA Range** (A)
    600 V
    SFA Range** (A)
    3-PHASE HP (UL) / Max. SFA**Contactor
    NEMA Size
    200 V230 V460 V600 V
    HPSFAHPSFAHPSFAHPSFA
    SSP3R-S1P-J-321~321~327.5321032203230321+
    SSP3R-S2-J-5222~5222~5215521552405250522
    SSP3R-S3P-J-8550~8050~7725803080608075773+
    SSP3R-S4-J-13080~DPV*N/A4012050130100124--4
    • Smartstart Pump Starter - 3-Phase, 50/60 Hz, 200~600 VAC
    • NEMA Type 3R Enclosed - Standard Starter
    • Disconnect not Included

    200~600 V Disconnect not Included NEMA Type 1 Enclosed

    Part Number200 V - 460 V
    SFA Range** (A)
    600 V
    SFA Range** (A)
    3-PHASE HP (UL) / Max. SFA**Contactor
    NEMA Size
    200 V230 V460 V600 V
    HPSFAHPSFAHPSFAHPSFA
    SSP1-S1P-J-321~321~327.5321032203230321+
    SSP1-S2-J-5222~5222~5215521552405250522
    SSP1-S3P-J-8550~8050~7725803080608075773+
    SSP1-S4-J-13080~DPV*N/A4012050130100124--4
    • Smartstart Pump Starter - 3-Phase, 50/60 Hz, 200~600 VAC
    • NEMA Type 1 Enclosed - Standard Starter
    • Disconnect not Included

    Factory Installable Options

    Part NumberDescription
    SSP-DHMDigital Hour Meter
    SSP-SRG240Surge Suppressor, 200/230 V
    SSP-SRG480Surge Suppressor, 460 V
    SSP-SRG600Surge Suppressor, 600 V
    SSP-RPLRun Pilot Light
    SSP-FPLFault Pilot Light
    SSP-TMRRun Timer (up to 12 hours)

    NEMA 3R Dimensions

    Combination Starter HeightWidthDepth
    SSP3R-S0-J-GXX221510
    SSP3R-S0P-J-GXX
    SSP3R-S1-J-GXX
    SSP3R-S1P-J-GXX
    SSP3R-S2-J-GXX
    SSP3R-S3-J-GXX321510
    SSP3R-S3P-J-GXXX
    SSP3R-S4-J-GXXX
    SSP3R-S1P-J-3216128
    SSP3R-S2-J-50
    SSP3R-S3P-J-80
    SSP3R-S4-J-130221510
    • *All measurements shown in inches

    NEMA 1 Dimensions

    Combination Starter HeightWidthDepth
    SSP1-S1P-J-32167.56
    SSP1-S2-J-50
    SSP1-S3P-J-8016128
    SSP1-S4-J-130221510
    • *All measurements shown in inches
  • Starter Type
    SSP - Smartstart Pump Starter
    Standard or Combination
    (Service Rated, Suitable for use as a Service Disconnect)
    NEMA Type 1 or 3R Enclosed
    User Interface
    Settings AdjustmentsInternal
    Hand-Off-AutoNEMA 3R Enclosed - Door mounted switch,
    NEMA 1 Enclosed - Hand-Off-Auto keypad
    Standard Control Operations
    InputsDry Auto RunN.O. dry contact closure
    Run TimerOptional - Starter will run for a user defined time (1/2-12hrs),
    then return to off until another run command is received
    OutputFault RelayN.O. 12-240VAC
    OperationalOverload TypeElectronic, I2t thermal trip curve
    Fault ResetManual
    Power Fail ModesSelectable: Return to Off mode or return to last mode
    (Hand, Off, or Auto)
    Environmental
    Ambient Operating Temp-5° to 140° F (-20° to 60° C)
    Ambient Storage Temp-5° to 185° F (-20° to 85° C)
    Relative Humidity5% to 95% non-condensing
    Motor ProtectionAdjustment / DescriptionDefault Setting
    Overload Current Setting RangeDiffers per modelPer SFA
    Overload Trip ClassClass S (Submersible)Always on
    UnderloadAdjustable Trip: 0%-100% of FLA0.7
    Cycle FaultTrip if cycle rate exceeds 20 starts/minuteAlways On
    StallTrips within 0.5 seconds (disabled during startup)Always On
    ProtectionAdjustment / DescriptionDefault Setting
    Current Phase UnbalanceOn/OffTrips within 3 sec @ 25% current unbalance.On
    *Trip threshold changes to 80% unbalance when switched to Off
    Locked Rotor Trips within 0.5 seconds
    Out of CalibrationTrips after 10 seconds if the FLA dial setting is incorrect
    (set above calculated FLA range), ie.
    Start current is outside of an acceptable range
    (fla setting * 5 < inrush < fla setting * 14).
    Max Time to StartRegardless of FLA or I2t curve, always trip at start
    if starting current is outside of an acceptable range
    (inrush / 5) and still decreasing after 10 seconds.